Explosion-Proof Hot Washer

SPECIFICATIONS:

3.5 GPM @ 3000 PSI, 130F
480V/3Ph/60Hz; operating current 57 amps
7.5 HP, TEFC, 1750 RPM motor with 1.15 service factor
Triplex ceramic plunger pump
38 KW electric heating elements & vessels
Water tight main electrical enclosure with On/Off controls and indicator lights for the electric motor and heating element.
Circuit breakers for the motor, primary transformer, and heating element circuits.
3/8" x 50' one wire braid hose
Detergent injector
Includes high temperature limit switch, pressure relief valve, water flow switch, temperature and pressure gauges.
Includes hour meter and shutdown timer.
Explosion-proof design, for uses in Class I Division I, Group C & D, Class II, Group F & G hazardous locations.
Self-certified to UL 60335-2-79, CSA E60335-2-79 and complies with OSHA Regulation 1910.303(a).
DNV 2.7-1 Certified Skid Mounted

Diesel Hot / Cold Washer

DieselHotColdWasherFront_small.png
DieselHotColdWasher_small.png

SPECIFICATIONS:

5.5 GPM @ 3500 PSI diesel driven high pressure, cold or hot water
Triplex plunger, oil bath, positive displacement water pump, belt drive 2000 watt generator, belt drive
21.6 HP (16.1 KW) Kubota diesel engine with combination Chalwyn high-speed shutdown, manual ESD, & spark arrestor
420,000 BTU/H input 120 volt, oil fired burner (#2 diesel) 40 (151.4 L) gallon fuel tank
Coast Guard approved fuel system
Horizontal mounted 1/2" Schedule 80 pipe heating coil (1.27 cm Sch 80 pipe heating coil)
Trigger type, insulated pistol grip shut-off gun
Upstream detergent metering valve Includes flow switch, high temperature limit, pressure relief valve, thermal relief valve, rupture disc, electronic fuel gauge, and stainless steel float tank with inlet water back flow prevention
Adjustable digital temperature control Frequency meter
Hour meter
Self-certified to UL 60335-2-79, CSA E60335-2-79 and complies with OSHA Regulation 1910.303(a).
DNV 2.7-1 Certified Skid Mounted